Water lubrication single-stage compression frequency conversion series

Feature: Screw block with single stage air compression
Advantages: Low compression level Low temperature rise Low air leakage Integrated shaft (direct drive) Benefit: 5% energy saving Feature: IE4 Permanent Magnet Motor / WEG Brand High Efficiency IE4 Motor Optional oil cooled engine Advantages : Engine efficiency 97% Benefit: 5% energy saving

Product advantages

 

Feature

Feature: Dual VFD System Benefits : Constant pressure output to eliminate pressure fluctuations and load shedding Constant outlet temperature at 80-85℃ Low inrush current to protect components Benefit: 15% energy savings

Benefits

Feature: Screw block with single stage air compression Advantages: Low compression level Low temperature rise Low air leakage Integrated shaft (direct drive) Benefit: 5% energy saving

Advantages

Feature: Dual VFD System Benefits : Constant pressure output to eliminate pressure fluctuations and load shedding Constant outlet temperature at 80-85℃ Low inrush current to protect components Benefit: 15% energy savings

Technical Parameters

ModelMaximum
Working Pressure
DURATIONKW Motor
Power
dB noiseCooling water inlet and
outlet
diameter
Cooling
Water
Inlet Water
Temperature-Desaturation

32%
coolant
L
Dimensiones
L*W*H
mm
Weight
kg
Inch air
outlet
barpsigm³/mincfm
SW-06A/W81160.7827.55.5583/4″1.510800X800X12004303/4″
101450.6521.18
SW-08A/W81161.1540.67.5583/4″210800X800X12004703/4″
101451.0236
12.51810.8128.6
SW-11A/W81161.5554.711601″2.5261150X755X13405803/4″
101451.3246.6
12.51811.0135.7
SW-15A/W81162.3081.215631″3.5261150X755X13406503/4″
101452.1274.8
12.51811.6056.5
SW-18A/W81163.10109.418.5651″4301400X900X14507051″
101452.6292.5
12.51812.1074.1
SW-22A/W81163.42120.722651″5301400X900X14507451″
101453.15111.2
12.51812.6292.5
SW-30A/W81165.05178.330671 1/2″7401550X1150X1550(A)11001 1/4″
101454.20148.3
12.51813.18112.31500X1150X1300(W)
SW-37A/W81166.10215.337671 1/2″9401550X1150X1550(A)11501 1/4″
101455.25185.3
12.51814.85171.21500X1150X1300(W)
SW-45A/W81167.60268.345681 1/2″10901980X1300X1760(A)13902″
101456.15217.1
12.51815.65199.41800X1300X1680(W)
SW-55A/W81169.60338.955701 1/2″121201980X1300X1760(A)14702″
101458.55301.8
12.51817.45263.01800X1300X1680(W)
SW-75A/W811613.00458.975731 1/2″181202100X1600X2000(A)22502″
1014511.42403.1
12.51819.85347.72200X1500X1800(W)1630
SW-90A/W811616.25573.690731 1/2″201802400X1600X2000(A26502 1/2″
1014514.55513.6
12.518112.30434.22200X1550X1800(W)2350
SW-110A/W811619.50688.4110782″241803000X1700X2250(A)31502 1/2″
1014516.80593.0
12.518115.15534.82200X1550X1800(W)2460
SW-132A/W811622.52795.0132782″302403000X1700X2250(A)35002 1/2″
1014520.30716.6
12.518118.25644.22200X1550X1800(W)2500
SW-160W811628.11992.3160803″352402700X1800X20503700DN80
1014524.50864.9
12.518122.15781.9
SW-185W811633.651187.8185803″383002700X1800X20503750DN80
1014528.51006.1
12.518124.5864.9
SW-200W811636.631293.0200804″423002700X1800X20503900DN100
1014532.751156.1
12.518127.50970.8
SW-220W811639.501394.4220804″473602700X1800X20504200DN100
1014535.801263.7
12.518129.501041.4
SW-250W811640.501429.7250804″583602700X1800X20504600DN100
1014536.301281.4
12.518132.501147.3

Note: air and water cooling.

Variable frequency technical parameters
ModelMaximum
Working Pressure
DURATIONKW Motor Power
dB noiseCooling water inlet and
outlet
diameter
Cooling
Water
InletWater
Temperature-Desaturation

32%
coolant
L
Dimensiones
L*W*H
mm
Weight
kg
Inch air
outlet
barpsigm³/mincfm
SWVC-06A/W81450.3-0.7810.6-27.55.5583/4″1.510800X800X12004603/4″
101450.2-0.657.1-22.9
SWVC-08A/W81160.35-1.1512.4-40.67.5583/4″210800X800X12005103/4″
101450.3-1.0210.6-36.0
12.51810.24-0.818.5-28.6
SWVC-11A/W81160.54-1.5519.1-54.711601″2.5261150X755X13406203/4″
101450.45-1.3215.9-46.6
12.51810.35-1.0112.4-35.7
SWVC-15A/W81160.75-2.3026.5-81.215631*3.5261150X755X13406703/4″
101450.65-2.1222.9-74.8
12.51810.6-1.6021.2-56.5
SWVC-18A/W81160.9-3.1031.8-109.418.5651″4301400X900X14507301″
101450.9-2.6231.8-92.5
12.51810.6-2.1021.2-74.1
SWVC-22A/W81161.1-3.4238.8-120.722651″5301400X900X14507801″
101450.97-3.1534.2-111.2
12.51810.85-2.6230.0-92.5
SWVC-30A/W81161.55-5.0554.7-178.330671 1/2″7401550X1150X-1550(A)11501 1/4″
101451.26-4.2044.5-148.3
12.51811.10-3.1838.8-112.31500X1150X-1300(W)
SWVC-37A/W81161.91-6.1067.4-215.337671 1/2″9401550X1150X-1550(A)12001 1/4″
101451.60-5.2556.5-185.3
12.51811.42-4.8550.1-171.21500X1150X-1300(W)
SWVC-45A/W81162.50-7.6088.3-268.345681 1/2″10901980X1300X-1760(A)14902″
101451.91-6.1567.4-217.1
12.51811.70-5.6560.0-199.41800X1300X-1680(W)
ModelMaximum
Working Pressure
DURATIONKW Motor
Power
dB noiseCooling water
inlet and
outlet
diameter

Cooling
Water
Inlet Water Temperature-Desaturation

32%
coolant
L
Dimensiones
L*W*H
mm
WeiWeight
kg
Inch air
outlet
barpsigm³/mincfm
SWVC-55A/W81163.0-9.60105.9-338.955701 1/2″121201980X1300X-1760(A)15702″
101452.56-8.5590.4-301.8
12.51812.30-7.4581.2-263.01800X1300X-1680(W)
SWVC-75A/W81163.95-13.00139.4-458.975731 1/2″181202100X1600X-2000(A)22502″
101453.40-11.42120.0-403.1
12.51813.0-9.85105.9-347.72200X1500X-1800(W)1750
SWVC-90A/W81165.0-16.25176.5-573.690731 1/2″201802400X1600X-2000(A)31502 1/2″
101454.30-14.55151.8-513.6
12.51813.72-12.30131.3-434.22200X1550X-1800(W)2450
SWVC-110A/W81166.0-19.50211.8-688.4110782″241803000X1700X-2250(A)31502 1/2″
101455.07-16.80179.0-593.0
12.51814.65-15.15164.1-534.82200X1550X-1800(W)2580
SWVC-132A/W81166.75-22.52238.3-795.0132782″302403000X1700X-2250(A)350021/2″
101456.0-20.30211.8-716.6
12.51815.07-18.25179.0-644.22200X1550X-1800(W)2700
SWVC-160A/W81168.5-28.11300.1-992.3160803″352402700X1800X20503900DN80
101457.6-24.50268.3-864.9
12.51816.7-22.15236.5-781.9
SWVC-185W814510-33.65353.0-1187.8185803″383002700X1800X20504050DN80
101458.72-28.5307.8-1006.1
12.51817.75-24.5273.6-864.9
SWVC-200W811611.2-36.63395.4-1293.0200804″423002700X1800X20504200DN100
101459.68-32.75341.7-1156.1
12.51819.2-27.50324.8-970.8
SWVC-220W811612.2-39.50430.7-1394.4220804″473602700X1800X20504400DN100
1014511.2-35.80395.4-1263.7
12.51819.0-29.50317.7-1041.4
SWVC-250W811613.5-40.50476.6-1429.7250804″583602700X1800X20504800DN100
1014512.3-36.30434.2-1281.4
12.518110.2-32.50360.1-1147.3
Application Area

Food industry, such as transportation, filling, packaging, and other processes.
In the medical field, gas is used in medicines, vaccines, etc., especially in hospitals.
In the textile industry, compressed air can affect the quality and hygiene of fabrics.
Process requirements such as the high-precision instrument industry and board manufacturing.
Laboratory applications, analytical tests, chemical tests, etc.