Permanent magnet variable frequency single-stage compression SVC series

Feature: Screw block with single stage air compression Advantages: Low compression level Low temperature rise Low air leakage Integrated shaft (direct drive) Benefit: 5% energy saving Feature: IE4 Permanent Magnet Motor / WEG Brand High Efficiency IE4 Motor Optional oil cooled engine Advantages : Engine efficiency 97% Benefit: 5% energy saving

Product advantages

 

Feature

Feature: Dual VFD System Benefits : Constant pressure output to eliminate pressure fluctuations and load shedding Constant outlet temperature at 80-85℃ Low inrush current to protect components Benefit: 15% energy savings

Benefits

Feature: Screw block with single stage air compression Advantages: Low compression level Low temperature rise Low air leakage Integrated shaft (direct drive) Benefit: 5% energy saving

Advantages

Feature: Dual VFD System Benefits : Constant pressure output to eliminate pressure fluctuations and load shedding Constant outlet temperature at 80-85℃ Low inrush current to protect components Benefit: 15% energy savings

Technical Parameters

ModelMaximum Working PressureProductivity (fad)Power
Electric motor
Appearance
Transmission
Noise LevelDiameter
Pipes
Exports
RefrigeratorSize (mm)Wes
barpsigm³/mincfmkwhpdbinchLLInHkg
SVC-08A7.51520.34~1.2012.00~42.367.510Integrated
shaft (direct drive)
603/4106506501015260
8.51230.32~1.1011.30~38.83
10.51230.26~1.029.18~36.01
12.51810.22~0.867.77~30.36
SVC-11A7.51090.45~1.7915.89~63.191115Integrated
shaft (direct drive)
603/4108807801080320
8.51230.42~1.6614.83~58.60
10.51520.37~1.4913.06~52.60
12.51810.30~1.2110.59~42.71
SVC-15A7.51090.66~2.5823.30~91.071520Integrated
shaft (direct drive)
653/4188807801080330
8.51230.61~2.3521.53~82.96
10.51520.52~2.0818.36~73.42
12.51810.42~1.8014.83~63.54
SVC-18A7.51090.76~3.1026.83~109.4318.525Integrated
shaft (direct drive)
651188808001350450
8.51230.74~2.9026.12~102.37
10.51520.63~2.5222.24~88.96
12.51810.53~2.1018.71~74.133/48807801080380
SVC-22A7.51091.00~3.7535.30~132.382230Integrated
shaft (direct drive)
651188808001350510
8.51090.87~3.5030.71~123.55
10.51520.74~2.9426.12~103.78
12.51810.61~2.4221.53~85.433/48807801080400
SVC-30A7.51091.37~5.3848.36~189.913040Integrated
shaft (direct drive)
681.52010009001420550
8.51231.34~5.0047.30~176.50
10.51521.10~4.4138.83~155.67
12.51810.87~3.4730.71~122.4918808001350530
SVC-37A7.51091.63~6.5157.54~229.803750Integrated
shaft (direct drive)
681.52010009001420600
8.51231.60~6.4156.48~226.27
10.51521.34~5.3647.30~189.21
12.51811.16~4.6240.95~163.09
SVC-45A7.51092.10~8.4074.13~296.524560Integrated
shaft (direct drive)
681.530108010001480750
8.51231.97~7.8869.54~278.16
10.51231.73~6.9361.07~244.63
12.51811.55~6.0054.72~211.80
ModelMaximum Working PressureProductivity (fad)Power
Electric motor
Appearance
Transmission
Noise LevelDiameter
Pipes
Exports
RefrigeratorSize (mm)Wes
barpsigm³/mincfmkwhpdbinchLLInHkg
SVC-55A7.51092.75~11.0097.08~388.305575Straight
Drive
72240140011001510950
8.51232.58~10.3091.07~363.59
10.51522.18~8.7076.95~307.11
12.51812.00~8.0070.60~282.40
SVC-75A7.51093.45~13.80121.79~487.1475100Straight
Drive
722601400110015101000
8.51233.25~13.00114.73~458.90
10.51522.88~11.50101.66~405.95
12.51812.55~10.6090.02~374.18
SVC-90A/W7.51094.13~17.80145.79~628.3490120Straight
Drive
75DN65702100137017002000
8.51234.00~17.20141.20~607.16
10.51523.48~14.60122.84~515.3822100137017001900
12.51813.08~12.30108.72~434.19
SVC-110A/W7.51095.50~22.00194.15~776.60110150Straight
Drive
75DN651002300155019002400
8.51235.13~21.00181.09~741.30
10.51524.47~18.00157.79~635.402100137017002200
12.51813.70~14.80130.61~522.44
SVC-132A/W7.51096.43~25.70226.98~907.21132175Straight
Drive
78DN801002900189019502800
8.51236.13~24.50216.39~864.85
10.51525.35~21.40188.86~755.42
12.51814.45~17.80157.09~628.34DN652300155019002600
SVC-160A/W7.51097.50~30.00264.75~1059.00160215Straight
Drive
78DN1001002900189020503500
8.51237.20~28.80254.16~1016.64
10.51525.87~23.50207.21~829.55DN802900189019503000
12.51815.25~21.00185.33~741.30
SVC-185A/W7.51098.63~34.50304.64~1217.85185250Straight
Drive
78DN1001502900189020504000
8.51238.25~33.00291.23~1164.90
10.51527.20~28.80254.16~1016.64
12.51815.87~23.50207.21~829.55DN802900189019503800
SVC-250A/W7.510910.90~43.80384.77~1546.14250340Straight
Drive
82DN1251503100200021005200
8.512310.70~43.00377.71~1517.90
10.5152///////
12.51818.30~33.00292.99~1164.90DN1002900189020504800

In accordance with Appendix E of ISO 1217, the complete set of equipment is freely supplied at an ambient temperature of 20°C and an absolute inlet pressure of 1 bar.
Sound pressure from 64 DB (a) according to Din en ISO 2151:2009
Technical specifications can be changed